MACHINING CASE / 04
Thin-Wall EMI Shielding Enclosure Cover.
A custom EMI shielding enclosure cover with ventilation-hole arrays, mounting holes and openings for electronic equipment — where thin frame meets heavy material removal.
- MATERIAL
- 6061-T651 aluminium
- FINISH / PROCESS
- Conductive conversion coating
- REPRESENTATIVE SIZE
- 426 × 221 × 36 mm
- KEY REQUIREMENT
- Flatness ≤ 0.05 mm, mating face

01
Machining challenges
A thin frame plus heavy material removal raises distortion risk, and ventilation-hole accuracy and conductive contact surfaces need tight control. The route manages stress relief and holds the cover with temporary supports through finish milling so flatness survives release.MANUFACTURING ROUTE
STEP 01
Rough machining
STEP 02
Stress relief
STEP 03
Datum and finish milling with temporary supports
STEP 04
Deburring and cleaning
STEP 05
Conductive conversion coating, masking, painting, screen printing
KEY CONTROL POINTS
—
What the route watches
- Mating-face flatness: ≤ 0.05 mm
- Hole-array spacing and position
- Opening dimensions
- Protection of conductive mating surfaces during finishing
DIMENSIONAL & SURFACE INSPECTION
—
How it gets verified
- CMM measurements, free state
- Flatness and hole-array checks
- Contact resistance on conductive areas
- Coating adhesion and appearance
- Marking position
The requirements and manufacturing route shown here apply to this project. New components are reviewed against their own drawings and agreed specifications — published values are project-specific requirements, not general capability limits.
Related
- Explore flanges & end covers (incl. EMI shielding)
- RF & Microwave Housing — brass, gold-plated